Confidentiality Usage
From Hiasobi - FHIR
Confidentiality (security) for resource content is managed as metadata
http://hl7.org/fhir/DSTU2/resource.html#Meta
Represented as security labels:
http://hl7.org/fhir/DSTU2/security-labels.html
In Hiasobi usage security is applied for 'confidentiality' on Condition or Procedure resources (as supported by the clinical systems)
There are two codes used:
- Confidential: Code = "R", System = "http://hl7.org/fhir/v3/Confidentiality", Display = "restricted"
- Normal: Code = "N", System = "http://hl7.org/fhir/v3/Confidentiality", Display = "normal"
These are applied on every Condition and Procedure resource Meta element.
Example
"resource": { "resourceType": "Condition", "id": "129", "meta": { "versionId": "20160723123649", "lastUpdated": "2016-07-23T12:36:49+00:00", security": [ { "system": "http://hl7.org/fhir/v3/Confidentiality", "code": "R", "display": "restricted" } ] }, "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>2016-07-23 Alcohol dependence</p></div>" }, "patient": { "reference": "Patient/35" }, "code": { "coding": [ { "system": "http://oridashi.com.au/system/code/bestpracticeterm", "code": "81", "display": "Alcohol dependence" }, { "system": "http://snomed.info/sct", "code": "66590003", "display": "Alcohol dependence" } ], "text": "Alcohol dependence" }, "category": { "coding": [ { "system": "http://snomed.info/sct", "code": "439401001", "display": "Diagnosis" } ] }, "clinicalStatus": "active", "verificationStatus": "confirmed", "onsetDateTime": "2016-07-23", "abatementBoolean": false }